CADEL SRL - STUFA A PELLET - page 59

59
NICE - MIRIAM - CRISTAL - PRETTY - DIANA - KRISS - MARY
EN
• External chimney flue entirely made up of insulated stainless steel pipes, i.e. with double wall of minimum
Ø120 mm: all must be firmly attached to the wall. For chimney against wind effects please (see
Fig. 5 a
pag. 54
).
• Ducting system through T-unions which enables an easy cleaning without disassembling the pipes.
We recommend to check with your chimney flue manufacturer the safety distances
which must be respected and the type of insulating material. The aforesaid regulations
are valid also for holes made on the wall (EN 13501 - EN 13063 - EN 1856 - EN 1806 - EN
15827).
8
FUEL
8.1
FUEL
• The type of fuel to use is only the pellets.
• Use top-quality pellets because they have influence in the calorific value and in ash remains.
• Pellets features are: dimension Ø6-7mm (D06 Class), maximum lenght 40 mm, calorific value 5kWh/
kg, humidity ≤ 10%, ash remains ≤ 0,7%, they must be correctly pressed and not much mealy, without
sizing agents, resins and other additives (it is advisable to use pellets in compliance with the regulation
EN14961-2 type ENplus-A1 ).
• Not adequate pellets cause a bad combustion, a frequent burning pot obstruction and exhaust conduits
obstruction. Further it decreases the calorific value, soils the glass and increases consumptions and ash
and unburnt granules quantity.
Humid pellets cause a bad combustion and running, so please assure you that they are
stored in dry places and far at least one meter from the stove and/or any other source
of heat.
• It is advisable to try different type of pellets available on the market and to choose that which gives the
best performance.
• The use of bad quality pellets can damage the stove so that the warranty and manufacturer liability fall.
• Do not use the appliance as waste inceneretor.
• On all our product are used high-quality materials such as stainless-steel, steel, cast iron, etc... These
materials, before being sold on the market, are tested in laboratory, but despite this on the components
which enable the pellets flow (auger) there could exist minimum differences in the material used, in
roughness and porosity, which could generate usual variations in fuel transportation (pellets), causing a
flame raising or drapping with a possible switching off at lower powers.
• Depending on the type of pellets it could be necessary a parameters adjustment, please contact an
Authorized Assistance Service.
9
INSTALLATION
9.1
INTRODUCTION
• The assembly position must be chosen depending on environment, outlet, chimney flue.
• Check with local authorities if there are any restrictive regulations which regard the combustible air inlet,
room ventilation, fume exhaust system together with chimney flue and chimney pot.
• The manufacturer declines any responsibility in case of installation which are not in compliance with
current regulations, in case of a wrong room ventilation system, in case of an electric connection which
is not in compliance with regulations and in case of a wrong use of the appliance.
• The installationmust beexecutedby an authorized technician, whomust release to the user adeclaration