IN CASE OF ANOMALY
13.1
ALARMS
Before of every intervention of the Authorized Technician, the same Technician has the
duty to check that the parameters of the mother board correspond with those of the
table you own.
In case of doubts regarding the use of the stove, please call ALWAYS the Authorized
Technician in order to avoid irreparable damages!
ALARM CAUSE
SOLUTION
INTERVENTION
AL 1 - BLACK
OUT
Power cut during
ignition phase.
Clean the burning pot and switch the stove on
again.
AL 2 - FUME
PROBE
Disconnected fume
temperature probe Have the stove checked.
Faulty fume
temperature probe Replace the fume probe.
AL 3 - HOT
FUME
Faulty fume probe
Replace the fume probe.
Faulty mother board Replace the electronic board.
The exchanger fan
does not work
Replace the ambient fan.
Too high pellet drop
value
Adjust the pellet loading.
AL 4 - FAN
FAILURE
Faulty protection fuse of
the fume fan
Replace the fuse (1,5A).
Faulty fume fan
The pellets can burn also thanks to the chimney flue
depression and without the aid of the fume fan.
Have the fume fan replaced immediately. It can
be noxious to health to let the stove running without
fume fan.